Gross bearing pressure, one-way (cantilever) shear and Whitney-block flexural design for a continuous strip footing under a bearing/shear wall, analyzed per foot of wall, by ACI 318-08.
Everything you have entered is in the address bar, so the link reproduces this exact calculation.
d = 10.69 in · all pass
| Check | Ref | Demand | Capacity | DCR | Governs | Status |
|---|---|---|---|---|---|---|
| Bearing (gross, service) | ASCE 7 §2.4 | 2.04 ksf | 3.00 ksf | 0.68 | Governing combo: D+L | PASS |
| One-way shear | ACI §11.2.1 / Eq. 11-3 | 1.27 kip | 10.54 kip | 0.12 | qu = 2.08 ksf (governing combo: 1.2D+1.6L) | PASS |
| Continuous-strip applicability | Modeling idealization, not a code check | 1.00 | 5.00 | 0.20 | wall length / B = 5.00 | PASS |
Mu = 2.34 kip.ft/ft, As req'd = 0.049 in²/ft
#5 @ 12.3 in o.c.
As = 0.0018·b·T = 0.302 in²/ft (temperature/shrinkage only)
#4 @ 7.9 in o.c.
| Check | Demand | Capacity | DCR | Status |
|---|---|---|---|---|
| Bearing (gross, service) | 2.037 ksf | 3.000 ksf | 0.679 | ✓ OK |
| One-way shear | 1.268 kip | 10.537 kip | 0.120 | ✓ OK |
Results are for preliminary sizing and educational use. They are not a design and must be reviewed, verified and sealed by a licensed or registered engineer before being used in construction.
wall-strip-footing-design v1.0.0 · ACI 318-08 · input ea77b2f181d25986